Brighteners: the distribution

The detail behind Optical Brighteners. Every figure here is computed from the M1 and M2 measurements shipped with the library, so anything on this page can be recomputed from the files rather than taken on trust.

FI — how far each sample moves when the UV comes on

ΔE00 between the M1 and the M2 reading of the same patch, across all 4253.

FISamplesShareWhat it means in practice
under 0.5111526.2%Effectively unaffected. The ink blocks the paper’s fluorescence.
0.5 – 1.078418.4%Measurable, below what anyone would notice side by side.
1.0 – 2.0133731.4%Around one step of the neutral ramp. Visible if you look.
2.0 – 3.067715.9%Comparable to the distance between neighbouring swatches.
3.0 – 5.03177.4%A different colour by any working tolerance.
over 5.0290.7%Unmistakable.

Median 1.15, mean 1.33, 95% of samples below 3.35. 2354 — 55% — move by more than 1.0.

The ten that move most

CodeNameFI
0P5.79Palladium7.34
N.93Light Pearl Gray6.09
1R6.71—5.97
0B5.92Alice Blue5.94
0Y1.88Birch5.89
N.90Frost5.87
0P4.90Blanched Lilac5.83
0G3.92Pale Ash5.82

The pattern is not subtle: they are all pale. A light, low-chroma ink lets most of the paper’s fluorescence through, so the sample inherits nearly the whole effect. A dense saturated ink blocks it. Which is why N.93 Light Pearl Gray — the lightest neutral, effectively the unprinted stock — sits near the top of the list, and why a deep blue does not appear on it at all.

The practical reading. If a design lives in pale tints on a brightened stock, the measurement condition is not a technicality — it is most of the difference between what you specified and what arrives.

OBA index — how much brightener reaches each sample

b*(M2) − b*(M1), which is the same quantity QuickChecker reports for a paper. Read against a sample it says how much of the stock’s brightener the ink lets through.

OBA indexSamplesShare
under 0.570416.5%
0.5 – 1.582319.3%
1.5 – 3.0125029.3%
3.0 – 5.0132431.1%
5.0 – 7.01573.7%
over 7.010.02%

The unprinted stock itself reads 6.46. Nothing printed on it can exceed that by much, and a sample near 0 is one whose ink is opaque to ultraviolet.

The three that read above the paper

CodeNameWhat it probably is
0P5.79PalladiumEither the ink carries a fluorescent pigment of its own, or that sheet was brighter than the reference on the day. Published as measured and flagged, not corrected — both explanations are worth being able to see.
0B5.92Alice Blue
0P4.90Blanched Lilac

Recomputing this yourself

Everything above comes from two numbers per sample that ship in the library files: the M1 colorimetry and the M2 colorimetry. FI is the ΔE00 between them; the OBA index is the difference of their b* values. Download CxF with all conditions and both are in front of you.

Read next